{"id":1653,"date":"2015-04-24T15:35:43","date_gmt":"2015-04-24T14:35:43","guid":{"rendered":"http:\/\/www.bussink.ch\/?p=1653"},"modified":"2018-05-23T17:57:36","modified_gmt":"2018-05-23T15:57:36","slug":"homelab-2015-upgrade","status":"publish","type":"post","link":"https:\/\/www.bussink.ch\/?p=1653","title":{"rendered":"Homelab 2015 Upgrade"},"content":{"rendered":"<p>Since my last major entry about my <a title=\"Homelab 2014 Upgrade\" href=\"http:\/\/www.bussink.ch\/?p=1450\" target=\"_blank\" rel=\"noopener noreferrer\">Homelab in 2014<\/a>, I have changed a few things. I added a 2nd cluster based on Apple MacMini (Late 2012), on which I run my OS X workloads, <a href=\"https:\/\/github.com\/vmware\/photon\" target=\"_blank\" rel=\"noopener noreferrer\">VMware Photon #CloudNativeApps<\/a> machines, the DevOps Management tools and the vRealize Automation deployed blueprints. This cluster was initially purchased &amp; conceived as a management cluster. The majority of my workload is composed of management, monitoring, analysis and infrastructure loads. It just made sense to swap the Compute and Management cluster around, and use the smaller one for Compute.<\/p>\n<div id=\"attachment_1655\" style=\"width: 632px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/Compute_Cluster.png\"><img aria-describedby=\"caption-attachment-1655\" loading=\"lazy\" class=\"wp-image-1655 size-full\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/Compute_Cluster.png\" alt=\"Compute_Cluster\" width=\"622\" height=\"375\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/Compute_Cluster.png 622w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/Compute_Cluster-300x181.png 300w\" sizes=\"(max-width: 622px) 100vw, 622px\" \/><\/a><p id=\"caption-attachment-1655\" class=\"wp-caption-text\">Compute Cluster<\/p><\/div>\n<p>The original cluster composed of three SuperMicro X9SRH-7TF described in my <a href=\"http:\/\/www.bussink.ch\/?p=1450\" target=\"_blank\" rel=\"noopener noreferrer\">Homelab 2014<\/a> article (more build pictures <a href=\"http:\/\/www.bussink.ch\/?p=1604\" target=\"_blank\" rel=\"noopener noreferrer\">here<\/a>) gave me some small issues.<\/p>\n<div id=\"attachment_1659\" style=\"width: 719px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/2014.jpg\"><img aria-describedby=\"caption-attachment-1659\" loading=\"lazy\" class=\"wp-image-1659 \" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/2014.jpg\" alt=\"2014\" width=\"709\" height=\"416\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/2014.jpg 1024w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/2014-300x176.jpg 300w\" sizes=\"(max-width: 709px) 100vw, 709px\" \/><\/a><p id=\"caption-attachment-1659\" class=\"wp-caption-text\">Homelab in December 2014.<\/p><\/div>\n<p>I&#8217;ve found that the Dual 10GbE X540 chipset on the motherboard does heat up a bit more than expected, and more than once (5x) I lost the integrated Dual 10GbE adapters on one of my hosts, requiring a host power off for ~20 minutes to cool down. In addition, a single 16G DDR3 DIMM was causing one host to freeze\u00a0once every ~12 days. All the host have run extensive 48 hours memtest86+ checks, but nothing was spotted. \u00a0When a frozen VSAN host rejoins the cluster you see the re-synchronization of the data, and at that time, I&#8217;m glad to have a 10GbE network switch. In the end, I followed a best practice for VSAN clusters, I extendd the cluster to 4 hosts.<\/p>\n<p>Beginning February I added a single <strong>Supermicro X10SRH-CLN4F<\/strong> server with a <a href=\"http:\/\/ark.intel.com\/products\/83356\/Intel-Xeon-Processor-E5-2630-v3-20M-Cache-2_40-GHz\" target=\"_blank\" rel=\"noopener noreferrer\">Intel Xeon E5-2630v3<\/a> (8 Cores @2.4Ghz and 64GB of DDR4 memory) to the cluster. This Supermicro <a href=\"http:\/\/www.supermicro.com\/products\/motherboard\/xeon\/c600\/x10srh-cln4f.cfm\" target=\"_blank\" rel=\"noopener noreferrer\">X10SRH-CLN4F<\/a> comes with 4 Intel Gigabit ports, an integrated LSI 3008 SAS 12Gb\/s adapter. I also added an Intel X540-T2 dual 10GbE adapter to bring it in line with the first three nodes.<\/p>\n<div id=\"attachment_1657\" style=\"width: 727px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/esx01.png\"><img aria-describedby=\"caption-attachment-1657\" loading=\"lazy\" class=\"wp-image-1657 size-full\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/esx01.png\" alt=\"esx01\" width=\"717\" height=\"523\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/esx01.png 717w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/esx01-300x219.png 300w\" sizes=\"(max-width: 717px) 100vw, 717px\" \/><\/a><p id=\"caption-attachment-1657\" class=\"wp-caption-text\">vSphere 6.0 on Supermicro X10SRH-CLN4F<\/p><\/div>\n<p>Having a fourth host means scaling up the VSAN Cluster with an additional SSD and two 4TB SAS drives.<\/p>\n<p>In the past month, the pricing of the <strong>Samsung 845DC Pro<\/strong> SSD have drop, to come in the $1\/GB range. The Samsung 845DC Pro is rated at 10 DWPD (Disk-Writes-Per-Day) or 7300 TBW (TeraBytes-Written-in-5-years), and its performance is documented\u00a0at 50&#8217;000 Sustained Write IOPS (4K) (Write IOPS Consistency at 95%) [Reference <a title=\"Samsung SSD 845DC Pro\" href=\"http:\/\/www.samsung.com\/global\/business\/semiconductor\/minisite\/SSD\/downloads\/document\/Samsung_SSD_845DC_PRO_Brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Samsung 845DC Pro PDF<\/a>, and <a href=\"http:\/\/www.thessdreview.com\/our-reviews\/samsung-845dc-pro-review-800gb-class-leading-speed-endurance\/\" target=\"_blank\" rel=\"noopener noreferrer\">thessdreview article<\/a>]. A fair warning for other poeple looking at the Samsung SSD 845DC Pro, it is not on the VMware <a href=\"http:\/\/vmwa.re\/vsanhcl\" target=\"_blank\" rel=\"noopener noreferrer\">VSAN Hardware Compatibility List<\/a>.<\/p>\n<p>Here is a screenshot of the disk group layout of the VSAN Cluster.<\/p>\n<div id=\"attachment_1658\" style=\"width: 810px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/vsan_disk_group.png\"><img aria-describedby=\"caption-attachment-1658\" loading=\"lazy\" class=\"wp-image-1658 \" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/vsan_disk_group.png\" alt=\"vsan_disk_group\" width=\"800\" height=\"424\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/vsan_disk_group.png 968w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/vsan_disk_group-300x159.png 300w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><p id=\"caption-attachment-1658\" class=\"wp-caption-text\">VSAN Disk Management<\/p><\/div>\n<p>The resulting VSAN configuration is now 28TB usable space.<\/p>\n<p><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/vsan.png\"><img loading=\"lazy\" class=\" size-full wp-image-1662 aligncenter\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/vsan.png\" alt=\"vsan\" width=\"445\" height=\"249\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/vsan.png 445w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/vsan-300x168.png 300w\" sizes=\"(max-width: 445px) 100vw, 445px\" \/><\/a><\/p>\n<p>Here is a screenshot of the current Management Cluster.<\/p>\n<div id=\"attachment_1663\" style=\"width: 810px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/mgmt_cluster.jpg\"><img aria-describedby=\"caption-attachment-1663\" loading=\"lazy\" class=\"wp-image-1663\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/mgmt_cluster.jpg\" alt=\"\" width=\"800\" height=\"491\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/mgmt_cluster.jpg 1050w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/mgmt_cluster-300x184.jpg 300w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/mgmt_cluster-1024x628.jpg 1024w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><p id=\"caption-attachment-1663\" class=\"wp-caption-text\">Management Cluster<\/p><\/div>\n<p>This cluster having grown, is now also generating additional heat. It&#8217;s been relocated in a colder room, and I had a <a href=\"http:\/\/en.wikipedia.org\/wiki\/Three-phase_electric_power\" target=\"_blank\" rel=\"noopener noreferrer\">Three Phase 240V 16A electricity line<\/a> put in.<\/p>\n<div id=\"attachment_1660\" style=\"width: 710px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/2015.jpg\"><img aria-describedby=\"caption-attachment-1660\" loading=\"lazy\" class=\" wp-image-1660\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/2015.jpg\" alt=\"Management Cluster (April 2015)\" width=\"700\" height=\"1101\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/2015.jpg 1280w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/2015-191x300.jpg 191w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/2015-651x1024.jpg 651w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/a><p id=\"caption-attachment-1660\" class=\"wp-caption-text\">Management Cluster (April 2015)<\/p><\/div>\n<p>My external storage is still composed of two Synology arrays. An old DS1010+ and a more recent DS1813+ with a DX513 extension. At this point, 70% of my virtual machine datasets are located on the VSAN datastore.<\/p>\n<div id=\"attachment_1661\" style=\"width: 810px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/ds1813-.jpg\"><img aria-describedby=\"caption-attachment-1661\" loading=\"lazy\" class=\"wp-image-1661 size-full\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2015\/04\/ds1813-.jpg\" alt=\"\" width=\"800\" height=\"531\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/ds1813-.jpg 800w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2015\/04\/ds1813--300x199.jpg 300w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><p id=\"caption-attachment-1661\" class=\"wp-caption-text\">Synology DS1813+ Storage Manager<\/p><\/div>\n<p>Reviewing this article, I realize this cannot quantify as a homelab anymore&#8230; its a home datacenter&#8230; guess I need a new #HomeDC hashtag&#8230;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Since my last major entry about my Homelab in 2014, I have changed a few things. I added a 2nd cluster based on Apple MacMini (Late 2012), on which I run my OS X workloads, VMware Photon #CloudNativeApps machines, the DevOps Management tools and the vRealize Automation deployed blueprints. This cluster was initially purchased &amp; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[253,9],"tags":[77,209,204,208,210,154],"_links":{"self":[{"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/posts\/1653"}],"collection":[{"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1653"}],"version-history":[{"count":13,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/posts\/1653\/revisions"}],"predecessor-version":[{"id":1889,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/posts\/1653\/revisions\/1889"}],"wp:attachment":[{"href":"https:\/\/www.bussink.ch\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1653"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1653"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}