{"id":411,"date":"2012-02-11T22:49:23","date_gmt":"2012-02-11T21:49:23","guid":{"rendered":"http:\/\/www.bussink.ch\/?p=411"},"modified":"2018-05-23T18:00:16","modified_gmt":"2018-05-23T16:00:16","slug":"using-vcenter-update-manager-for-hp-esxi-installations","status":"publish","type":"post","link":"https:\/\/www.bussink.ch\/?p=411","title":{"rendered":"Using vCenter Update Manager for HP ESXi installations"},"content":{"rendered":"<p>This post will explain how to use the vCenter Update Manager to create a custom Hewlett-Packard Extensions baseline, so that you can install the HP Drivers on your ESXi install and the HP CIM Management Tools.<\/p>\n<p>Having just purchased a set of HP Proliant ML110 G7, I found out that HP has release at least two sets of drivers for ESXi 5.0.<\/p>\n<p>The first one is the <a title=\"VMware ESXi 5.0 Driver CD for the HP SmartArray\" href=\"http:\/\/downloads.vmware.com\/d\/details\/dt_esxi50_hp_hpsa_500240\/dHRAYnRAZWpiZHAlJQ==\" target=\"_blank\">VMware ESXi 5.0 Driver CD for the HP SmartArray<\/a>\u00a0version 5.0.0-24.0 released on\u00a02011\/08\/22. I recommend that you download this driver from the VMware website on your vCenter and extract it in a\u00a0convenient\u00a0place, as we will need the hpsa-500-5.0.0-offline_bundle-537239.zip file. We will come back to this file later.<\/p>\n<p>The second one is the <a title=\"HP ESXi 5.0 Offline Bundle\" href=\"http:\/\/h20000.www2.hp.com\/bizsupport\/TechSupport\/SoftwareDescription.jsp?lang=en&amp;cc=us&amp;prodTypeId=15351&amp;prodSeriesId=3884310&amp;prodNameId=3884311&amp;swEnvOID=4115&amp;swLang=8&amp;mode=2&amp;taskId=135&amp;swItem=MTX-dff3173d40bd45b094300e80c1\" target=\"_blank\">HP ESXi 5.0 Offline Bundle<\/a> now in version 1.1 since December 2011. This bundle contains multiple drivers such as the HP Common Information Model (CIM) Providers, HP Integrated Lights-Out (iLO) driver and HP Compaq ROM Utility (CRU) driver. Download this file but don&#8217;t extract it. We will use the file\u00a0hp-esxi5.0uX-bundle-1.1-37.zip as is.<\/p>\n<p>On your vCenter, jump to the Update Manager Administration pane, and select the Import Patches option.<\/p>\n<p><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a01-Import-Patches.png\"><img loading=\"lazy\" class=\"alignnone  wp-image-415\" title=\"a01 - Import Patches\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a01-Import-Patches-1024x237.png\" alt=\"\" width=\"819\" height=\"190\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a01-Import-Patches-1024x237.png 1024w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a01-Import-Patches-300x69.png 300w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a01-Import-Patches.png 1450w\" sizes=\"(max-width: 819px) 100vw, 819px\" \/><\/a><\/p>\n<p>We first import the HP SmartArray Driver<\/p>\n<div id=\"attachment_416\" style=\"width: 554px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a02-Import-hpsa-driver.png\"><img aria-describedby=\"caption-attachment-416\" loading=\"lazy\" class=\" wp-image-416 \" title=\"Import hpsa-500-5.0.0-offline_bundle\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a02-Import-hpsa-driver.png\" alt=\"\" width=\"544\" height=\"297\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a02-Import-hpsa-driver.png 755w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a02-Import-hpsa-driver-300x163.png 300w\" sizes=\"(max-width: 544px) 100vw, 544px\" \/><\/a><p id=\"caption-attachment-416\" class=\"wp-caption-text\">Import hpsa-500-5.0.0-offline_bundle<\/p><\/div>\n<div id=\"attachment_417\" style=\"width: 558px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a03-Importing-hpsa-patch.png\"><img aria-describedby=\"caption-attachment-417\" loading=\"lazy\" class=\" wp-image-417  \" title=\"Importing HP SmartArray Driver for ESX\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a03-Importing-hpsa-patch.png\" alt=\"\" width=\"548\" height=\"238\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a03-Importing-hpsa-patch.png 951w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a03-Importing-hpsa-patch-300x129.png 300w\" sizes=\"(max-width: 548px) 100vw, 548px\" \/><\/a><p id=\"caption-attachment-417\" class=\"wp-caption-text\">Importing HP SmartArray Driver for ESX<\/p><\/div>\n<p>We then import the HP ESXi 5.0 Offline Bundle<\/p>\n<div id=\"attachment_418\" style=\"width: 533px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a04-Import-hp-esxi5.0-bundle.png\"><img aria-describedby=\"caption-attachment-418\" loading=\"lazy\" class=\" wp-image-418    \" title=\"Import HP-ESXi5.0-bundle-1.1.37\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a04-Import-hp-esxi5.0-bundle.png\" alt=\"\" width=\"523\" height=\"285\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a04-Import-hp-esxi5.0-bundle.png 754w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a04-Import-hp-esxi5.0-bundle-300x163.png 300w\" sizes=\"(max-width: 523px) 100vw, 523px\" \/><\/a><p id=\"caption-attachment-418\" class=\"wp-caption-text\">Import HP-ESXi5.0-bundle-1.1.37<\/p><\/div>\n<div id=\"attachment_419\" style=\"width: 563px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a05-Import-patch.png\"><img aria-describedby=\"caption-attachment-419\" loading=\"lazy\" class=\" wp-image-419   \" title=\"Import HP-ESXi5.0-bundle-1.1.37\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a05-Import-patch.png\" alt=\"\" width=\"553\" height=\"255\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a05-Import-patch.png 898w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a05-Import-patch-300x138.png 300w\" sizes=\"(max-width: 553px) 100vw, 553px\" \/><\/a><p id=\"caption-attachment-419\" class=\"wp-caption-text\">Import HP-ESXi5.0-bundle-1.1.37<\/p><\/div>\n<p>And we now see both offline bundles in the Patch Repository<\/p>\n<div id=\"attachment_420\" style=\"width: 541px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a06-Update-Manager-HP-patches.png\"><img aria-describedby=\"caption-attachment-420\" loading=\"lazy\" class=\" wp-image-420   \" title=\"Patch Repository\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/a06-Update-Manager-HP-patches-1024x153.png\" alt=\"\" width=\"531\" height=\"79\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a06-Update-Manager-HP-patches-1024x153.png 1024w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a06-Update-Manager-HP-patches-300x44.png 300w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/a06-Update-Manager-HP-patches.png 1577w\" sizes=\"(max-width: 531px) 100vw, 531px\" \/><\/a><p id=\"caption-attachment-420\" class=\"wp-caption-text\">Patch Repository<\/p><\/div>\n<p>We will now create a new Baseline Extension for these offline patches so we can apply them to our HP servers.<\/p>\n<div id=\"attachment_428\" style=\"width: 545px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b02-Create-a-new-Baseline.png\"><img aria-describedby=\"caption-attachment-428\" loading=\"lazy\" class=\" wp-image-428  \" title=\"Create a new Baseline - Host Extension\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b02-Create-a-new-Baseline.png\" alt=\"\" width=\"535\" height=\"403\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b02-Create-a-new-Baseline.png 743w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b02-Create-a-new-Baseline-300x226.png 300w\" sizes=\"(max-width: 535px) 100vw, 535px\" \/><\/a><p id=\"caption-attachment-428\" class=\"wp-caption-text\">Create a new Baseline - Host Extension<\/p><\/div>\n<p>Add the HP Drivers and Tools to the new Host Extension<\/p>\n<div id=\"attachment_429\" style=\"width: 562px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b03-Save-HP-Drivers-and-Tools.png\"><img aria-describedby=\"caption-attachment-429\" loading=\"lazy\" class=\" wp-image-429  \" title=\"Add HP Drivers to Host Extension\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b03-Save-HP-Drivers-and-Tools-1024x466.png\" alt=\"\" width=\"552\" height=\"251\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b03-Save-HP-Drivers-and-Tools-1024x466.png 1024w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b03-Save-HP-Drivers-and-Tools-300x136.png 300w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b03-Save-HP-Drivers-and-Tools.png 1228w\" sizes=\"(max-width: 552px) 100vw, 552px\" \/><\/a><p id=\"caption-attachment-429\" class=\"wp-caption-text\">Add HP Drivers to Host Extension<\/p><\/div>\n<p>And save the New Baseline<\/p>\n<div id=\"attachment_430\" style=\"width: 533px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b04-Save-new-Baseline.png\"><img aria-describedby=\"caption-attachment-430\" loading=\"lazy\" class=\" wp-image-430  \" title=\"Save new Baseline\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b04-Save-new-Baseline.png\" alt=\"\" width=\"523\" height=\"363\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b04-Save-new-Baseline.png 791w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b04-Save-new-Baseline-300x208.png 300w\" sizes=\"(max-width: 523px) 100vw, 523px\" \/><\/a><p id=\"caption-attachment-430\" class=\"wp-caption-text\">Save new Baseline<\/p><\/div>\n<p>Lets attach this new Baseline Host Extension to our HP ML110 G7 Cluster and Scan the Cluster.<\/p>\n<div id=\"attachment_431\" style=\"width: 527px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b05-Attach-new-Baseline-to-Cluster-and-Scan.png\"><img aria-describedby=\"caption-attachment-431\" loading=\"lazy\" class=\" wp-image-431   \" title=\"Attach new Baseline to Cluster and Scan\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b05-Attach-new-Baseline-to-Cluster-and-Scan-1024x300.png\" alt=\"\" width=\"517\" height=\"151\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b05-Attach-new-Baseline-to-Cluster-and-Scan-1024x300.png 1024w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b05-Attach-new-Baseline-to-Cluster-and-Scan-300x88.png 300w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b05-Attach-new-Baseline-to-Cluster-and-Scan.png 1855w\" sizes=\"(max-width: 517px) 100vw, 517px\" \/><\/a><p id=\"caption-attachment-431\" class=\"wp-caption-text\">Attach new Baseline to Cluster and Scan<\/p><\/div>\n<p>We can now Remediate our HP Proliant ML110 G7 host with the new Host Extension. Please note that you cannot remediate VMware Patches and the Host Extensions at the same time. You will need to do this in two passes.<\/p>\n<p>Here is the Hardware Status of an HP ML110 G7 before applying the HP Host Extension patches<\/p>\n<div id=\"attachment_433\" style=\"width: 550px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b07-ML110G7-Prior-to-HP-Drivers-and-Tools.png\"><img aria-describedby=\"caption-attachment-433\" loading=\"lazy\" class=\" wp-image-433   \" title=\"ML110G7 Prior to HP Drivers and Tools\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b07-ML110G7-Prior-to-HP-Drivers-and-Tools.png\" alt=\"\" width=\"540\" height=\"283\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b07-ML110G7-Prior-to-HP-Drivers-and-Tools.png 877w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b07-ML110G7-Prior-to-HP-Drivers-and-Tools-300x157.png 300w\" sizes=\"(max-width: 540px) 100vw, 540px\" \/><\/a><p id=\"caption-attachment-433\" class=\"wp-caption-text\">ML110G7 Prior to HP Drivers and Tools<\/p><\/div>\n<p>and after having the remediation.<\/p>\n<div id=\"attachment_434\" style=\"width: 559px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b08-ML110G7-with-Storage-Information-SmartArray-Driver.png\"><img aria-describedby=\"caption-attachment-434\" loading=\"lazy\" class=\" wp-image-434    \" title=\" ML110G7 with Storage Information &amp; SmartArray Driver\" src=\"http:\/\/www.bussink.ch\/wp-content\/uploads\/\/2012\/02\/b08-ML110G7-with-Storage-Information-SmartArray-Driver.png\" alt=\"\" width=\"549\" height=\"336\" srcset=\"https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b08-ML110G7-with-Storage-Information-SmartArray-Driver.png 880w, https:\/\/www.bussink.ch\/wp-content\/uploads\/2012\/02\/b08-ML110G7-with-Storage-Information-SmartArray-Driver-300x183.png 300w\" sizes=\"(max-width: 549px) 100vw, 549px\" \/><\/a><p id=\"caption-attachment-434\" class=\"wp-caption-text\">ML110G7 with Storage Information &amp; SmartArray Driver<\/p><\/div>\n<p>Thanks to these drivers, we could now see the HP SmartArray Array Status if there where any disks attached to it.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This post will explain how to use the vCenter Update Manager to create a custom Hewlett-Packard Extensions baseline, so that you can install the HP Drivers on your ESXi install and the HP CIM Management Tools. Having just purchased a set of HP Proliant ML110 G7, I found out that HP has release at least [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":434,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[9],"tags":[25,34,35],"_links":{"self":[{"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/posts\/411"}],"collection":[{"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=411"}],"version-history":[{"count":24,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/posts\/411\/revisions"}],"predecessor-version":[{"id":638,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/posts\/411\/revisions\/638"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=\/wp\/v2\/media\/434"}],"wp:attachment":[{"href":"https:\/\/www.bussink.ch\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=411"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=411"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bussink.ch\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=411"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}